REPRESENTATIVE OFFICE
IN YOUR REGION
VMP Holding JSC
Ekaterinburg,
25 Tkachey str.,

tel.: +7 343 357-30-97,
+7 343 357-30-79
e-mail: office@fmp.ru



VMP in social networks:

QUICK-DRYING
MATERIAL
ATMOSPHERE-RESISTANT
MATERIAL
HEAT-RESISTANT
MATERIAL
THICK-LAYERED
MATERIAL
FOR APPLICATION AT
NEGATIVE
TEMPERATURE
SINGLE-PACKED
MATERIAL
ST 2, ST 3 SURFACE
PREPARATION DEGREE
FOR USE AT
SEA AND FRESH
WATER
FOR USE WHEN
EXPOSED TO OIL
AND OIL PRODUCTS
ZINC-FILLED
MATERIAL
MATERIAL WITH
ANTICORROSIVE
PIGMENTS
MATERIAL WITH
CORROSION INHIBITOR
MATERIAL WITH
ANTISTATIC PROPERTIES

ISOLEP®-arctic

ISOLEP®-arctic
TS 20.30.12-127-12288779-2020
primer/finish
Double-packed
Colour: red-brown, and white, black, red or others as agreed with customer

Description

ISOLEP-arctic is a two-component polyamine cured high solids (not more than 95 %) epoxy coating.

It provides high resistance against impacts and abrasion, has a low coefficient of friction against ice, helping to increase the ice-passability of ships and reduce fuel consumption.

The coating can be used in all macroclimatic zones, including the conditions of the Far North and the Arctic with operating temperatures down to -70 °C.

Recommended use

Designed to protect the underwater part of ship hulls, including icebreakers of Group 1 Classes I and II and for ice class ships of Group 2 Classes I and II in accordance with the requirements of clause 6.5.3 Part XIII “Rules for the classification and construction of sea-going ships "(ed. 2023)., can be used with 

cathodic protection.

Can be used for anti-corrosion protection of structures operated in sea and fresh water (during immersion), under conditions of exposure to highly aggressive environments, for the protection of hydraulic structures (sheet piling and quay walls, supports of oil berths, ship locks, etc.).

The coating is resistant to fresh, sea and mineralized water, as well as to spills of solutions of salts, acids, alkalis, oil and petroleum products, and detergents.

Can be used in new construction or major renovations as a stand-alone coating, or in a system with anti-fouling topcoats VINICOR-marin AF, VINICOR-marin AF/S, with topcoat POLYTON-UR (UV), as well as with other epoxy-based coatings according to in agreement with the VMP.

Surface preparation

New steel surfaces and coating total overhaul:
  • degrease the metal surface to the first degree in accordance with GOST 9.402;
  • remove salts by fresh water;
  • abrasive blasting from scale and rust to degree 2 according to GOST 9.402 (Sa 2 ½ or Sa 3 ISO 8501-1) with a sharp-edged surface profile with roughness 75-115 μm, segment 2-3 of ISO comparator G (ISO 8503-1);
  • remove dust.
Repair and maintenance of ISOLEP-arctic coating:
The choice of coating repair technology is determined after assessing its condition, depending on the degree and nature of the damage.
Spot repair of the coating is carried out with the following operations:
  • degrease the metal surface to the first degree in accordance with GOST 9.402;
  • remove salts by fresh water;
  • clean damaged areas with power hand tools from rust to P St 2 (ISO 8501-2);
  • remove dust.

When carrying out repair work it is allowed to clean by water jetting to Wa 2 and flash rust grade not lower than M (ISO 8501-4).
The content of chloride on the steel surface immediately before application of ISOLEP-arctic should not exceed 50 mg/m2 (ISO 8502-9)
The time between surface preparation and painting should not exceed 6 hours. When painting in industrial premises, it is allowed to increase the time interval to 16 hours while maintaining the quality of surface preparation.
Before applying the second layer of ISOLEP-arctic or top coats coating should be cleaned of dirt, degreased and dedusted.

Application

It is recommended to apply the material at an ambient temperature of -5 to +40 °C and a relative humidity of up to 80 %.
The temperature of the surface to be painted must be at least 3 °C above the dew point.
The temperature of the base, curing agent and the material itself must be at least +20 °C.

  • before use, mix the base until smooth;
  • add a curing agent to the base with constant stirring, mix thoroughly; if necessary, dilute to working viscosity.

The heating of the mixture to the working parameters is regulated by switching the heating of the hose on and off. The viability of the mixture at a temperature of 40-50 °C is 5 minutes.
The mixing ratio of the components is controlled by the pump pressure and the color of the outgoing paint (if the mixing ratio of the components is violated, the color of the paint becomes non-uniform).
When carrying out repair work and painting small areas, it is allowed to apply ISOLEP-arctic with a brush. The material must be mixed in the indicated ratio and diluted with SOLV-EP solvent to the working viscosity, but not more than 7 % by weight. After mixing it must be used up within 20 minutes.
After completion of work, all painting equipment must be washed with SOLV-EP solvent, or solvents646, R-4, 647, 649.
ATTENTION!!! The pot life depends on the quantity, the initial temperature of the components, the temperature of the mixture and the environmental parameters. Increasing the viscosity of the paint can lead to equipment failure. When performing work, it is necessary to follow the instructions for using the equipment.

The maximum holding time before overcoating should be no more than 7 days.
If the maximum overcoating interval is exceeded:

  • before applying the subsequent layer of ISOLEP-arctic, roughen the coating with light blasting or a mechanical tool;

  • before applying POLYTON-UR (UV) top coat – clean the ISOLEP-arctic coating from dirt and chalking products by washing with clean fresh water under pressure, dry the surface, apply the ISOLEP-pro as an intermediate layer to ensure interlayer adhesion in the anti-corrosion coating system ISOLEP-arctic +POLYTON-UR (UV).
The optimal coating holding time before use is at least 7 days at (20±2)°С.
The maximum overlap time must not be exceeded.
The use of antifouling topcoats, the maximum and minimum overcoating time must be agreed with the VMP.

Storage and handling

ISOLEP-arctic is supplied as a set: The base and the curing agent packed in metal containers, depending on the set weight.

Storage conditions - in accordance with GOST 9980.5 (at ambient temperatures from minus 40 to plus 40 °С). In storage the package shall be protected from lasting direct sunlight and atmospheric condensation.

It is allowed to store the package with enamel -primer components under direct sunlight, however not more than 3 hours.

The shelf life of the base is 24 months, of the curing agent – 12 months starting with the date of manufacture.

Precautions

When working with the enamel-primer one shall observe the existing sectoral standard norms and requirements and safety measures as specified on the package label.

One shall use personal protective equipment (goggles, face masks and respirators) and avoid inhalation of solvents and contact of the composition substances with skin, eye mucosa, respiratory channels; use inside the premises is allowed only in case sufficient ventilation is provided.

ISOLEP-arctic is classified as fire-hazardous material.

The information is of general character, without consideration to the object specific nature. Use of materials for other purposes not specified here or in case other influencing factors are present shall be approved by the  VMP Holding CJSC  in writing. In case of absence of such approval the manufacturer is not held liable for the improper use of the material and the buyer falls from the right to present claims connected with the coating quality.

Compatible materials:

You can order products and get advice of how to use materials by calling: 8-800-500-54-00, +7 343 357-30-97, 385-79-00 or by sending an On-line request

You can also purchase products from official representatives of the VMP in Russian regions, countries of near and far abroad.