One-pack alkyd primer enamel. It contains fire retardants, prevents fire propagation, does not emit
executive amounts of smoke and toxic products during combustion.
It is designed for painting evacuation routes, internal residential, service and special premises of
ships of unrestricted navigation, devices, mechanisms and equipment to which the increased safety
requirements are applied and also for protective-decorative painting of metal and wooden surfaces.
It is used as:
an independent coating;
a finishing layer in complex coating systems with VINICOR primer enamel, VINICOR-express-02 primer and other materials on epoxy ether, epoxy-urethane, polyurethane, epoxy, vinyl-epoxy, phenol-alkyd, acrylic, chlorinated rubber and alkyd bases.
State registration certificate No. RU.78.01.34.008.Е.001521.06.20 dated June 25th, 2020.
Certificate of type approval: OF RUSSIAN MARITIME REGISTER OF SHIPPING No. 20.07848.120
(Material with slow fire propagation characteristics, does not emit executive amounts of smoke and toxic
products during combustion).
It has a certificate of the voluntary certification system of the Russian River Register No. РОСС
RU.РО00.Н00355.
Primed surface
Before applying the subsequent layers, the coating of the underlying layer must be cleaned of dirt,
degreased, if necessary, free from dust and moisture.
If the maximum recoating interval of the primer is exceeded, additional measures are required to
ensure the adhesion between layers (surface sweeping).
Steel surface:
degrease the metal surface to the first grade according to GOST 9.402;
clean from scale, rust and traces of old paint by abrasive blasting to a grade no lower than Sa 2 according to ISO 8501-1 or with power-driven hand tools to the St 3 grade according to ISO 8501-1;
remove dust.
Aluminum surface:
degrease the metal surface to the first grade according to GOST 9.402;
manual or mechanized cleaning using sandpaper or non-metallic abrasive for creating a rough surface;
remove dust.
The coating must be dry, clean and free of oil and dust before applying the subsequent layers.
The material is packed in metal buckets and cans.
Storage conditions in accordance with GOST 9980.5 (at ambient temperatures from minus 40 to plus 40 °С). The container with the material must not be stored near hear sources and exposed to precipitation and direct sunlight.
Guaranteed storage life of the primer enamel: 18 months from the date of manufacture.
When working, one shall observe the corresponding industrial standards, requirements and safety measures indicated on the container label.
Use personal protective equipment (goggles, masks, respirators), avoid inhalation of thinners during evaporation and contact of the material or its components with skin, eye and respiratory ways mucous membrane; use the material indoors only with sufficient ventilation.
The materials are flammable!
The information is of general character, without consideration to the object specific nature. Use of materials for other purposes not specified here or in case other influencing factors are present shall be approved by the VMP Holding CJSC in writing. In case of absence of such approval the manufacturer is not held liable for the improper use of the material and the buyer falls from the right to present claims connected with the coating quality.